Rolă 500m cablu UTP Cat.6a NETSET U/UTP 6A B2ca s1a,d1,a1 LSOH

Cod: E1618_500
2703,68 Lei
Preţ cu TVA Rabat Cant. Validitate
2703,68 Lei 0 % de la 1 buc.
Disponibil

Garanție

Garanţie - 15 ani.

Suport tehnic

Detalii

NETSET cables are compliant with the Construction Products Regulation (CPR) and EN 50575 harmonized European standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables for use in construction works.
The requirements for using cables with a specific reaction to fire class in a given type of building should be based on a risk analysis made by the installation designer or other national formal and legal documents. The CPR Directive does not impose on the EU Member States the requirements for types of buildings and associated cables with specific fire reaction classes. The reaction to fire class of cables and other conductors installed within escape routes should not be less than B2ca-s1b, d1, a1.
According to guidelines of the Association of Polish Electrical Engineers guidelines, CPR class B2ca cable must be installed in escape routes:
    high-rise buildings (WW) with a height of more than 55 m above ground level
  • high-rise buildings (W) with a height of more than 25 m to 55 m above ground level or residential buildings with the number of floors above ground level from 9 to 18 inclusive
  • buildings in human risk category ZL I with rooms intended for simultaneous presence of more than 50 people who are not permanent users, and not intended primarily for use by people with reduced mobility
  • buildings in human risk category ZL II – intended primarily for use by people with reduced mobility, such as hospitals, nurseries, kindergardens, nursing homes
  • buildings in human risk category ZL III – commercial buildings not classified unser ZL I and ZL II
  • buildings in human risk category ZL IV – residential
  • Buildings in human risk category ZL V – collective residence not classified under ZL I and ZL II
  • PM and IN buildings (production buildings, warehouses, livestock etc.).
NETSET U/FTP 6A is a top quality indoor FTP CAT 6A twisted-pair cable designed for use in professional computer networks inside buildings. Shielding layers made of aluminum foil minimize crosstalk between pairs and interference with the external environment.
Key features of the NETSET U/UTP Category 6A E1618 twisted pair cable:
  • top quality materials, made to tight specifications, proven with a 15-year quality guarantee,
  • parameters by far exceeding the requirements of category 6A
  • pre-production quality control of raw materials and post-production quality control of the finished product,
  • meter marker,
  • single stranded copper conductors with a diameter of Ø 0.565 mm (23 by AWG),
  • conductor insulation made of polyethylene Skin-foam-skin PE, conductor insulation colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue,
  • insulated conductors twisted in pairs,
  • cable sheath made of LSZH, outer diameter Ø 7.5 mm,
  • error in printing meter max. 0.5%.
The NETSET U/UTP cat. 6A E1618 twisted pair cable has been manufactured in accordance with the standards:
  • General requirements for category 6A
    • ISO/IEC 11801:2011 (Ed. 2.2)
    • IEC 61156-5:2012 (Ed. 2.1)
    • EN 50173-1:2011
    • EN 50173-2:2007 A1:2010
    • EN 50288-10-1:2012
    • ANSI/TIA-568-C.2:2009
  • Flammability standards
    • IEC 60332-1-1:2015 (Ed. 1.1) / IEC 60332-1-2:2015 (Ed. 1.1)
    • IEC 60754-1:2011 (Ed. 3.0) / IEC 60754-2:2011 (Ed. 2.0)
    • IEC 61034-1:2013 (Ed. 3.1) / IEC 61034-2:2013 (Ed. 3.1)
  • Reaction to fire
    • Classification B2ca-s1a-d1-a1
    • EN 50575:2014 including amendment A1:2016
    • EN 60332-1-2:2004 including amendment A1:2015
    • EN 13501-6:2014
The cable comes with a 15-year warranty
The manufacturer guarantees the stability of parameters for at least 15 years, on the condition that the cable is packed, transported, installed, and used according to adequate European standards (among others E-79100 and EN 50174-1), within the permissible environmental conditions.
The NETSET U/UTP Category 6A E1617 twisted pair cable is intended for use in an environment with temperature from -30oC to 50 oC. Installation temperature not lower than 0oC and not higher than 50oC. The bending radius should not be less than 8 times the outside diameter.
Test results
  • Return Loss
Frequency [MHz] Result [dB]
1 20
4 23
8 24.5
10 25
16 25
20 25
25 24.3
31.25 23.6
62.5 21.5
100 20.1
200 18
250 17.3
300 16.8
500 15.2
The return loss graph of the cable compared with the EN 50173 standard.
  • Attenuation
Frequency [MHz] Result [dB/100m]  
1 2.1  
4 3.8  
8 5.3  
10 5.9  
16 7.5  
20 8.4  
25 9.4  
31.25 10.5  
62.5 15  
100 19.1  
200 27.6  
250 31.1  
300 34.3  
500 45.3  
  • NEXT
Frequency [MHz] Result [dB]
1 74.3
4 65.3
8 60.8
10 59.3
16 56.2
20 54.8
25 53.3
31.25 51.9
62.5 47.4
100 44.3
200 39.8
250 38.3
300 37.1
500 33.8
The NEXT (near end crosstalk) graph of the cable compared with the EN 50173 standard.
  • PSNEXT
Frequency [MHz] Result [dB]
1 72.3
4 63.3
8 58.8
10 57.3
16 54.2
20 52.8
25 51.3
31.25 49.9
62.5 45.4
100 42.3
200 37.8
250 36.3
300 35.1
500 31.8
The PSNEXT (power sum near end crosstalk) graph of the cable compared with the EN 50173 standard.
  • ELFEXT
Frequency [MHz] Result [dB]
1 68
4 56
8 49.9
10 48
16 43.9
20 42
25 40
31.25 38.1
62.5 32.1
100 28
200 22
250 20
300 18.5
500 14
The ELFEXT graph of the cable compared with the EN 50173 standard.
  • PSELFEXT
Frequency [MHz] Result [dB]
1 65
4 53
8 46.9
10 45
16 40.9
20 39
25 37
31.25 35.1
62.5 29.1
100 25
200 19
250 17
300 15.5
500 11
The PSELFEXT graph of the cable compared with the EN 50173 standard.

Specificații

Nume
Tip produs cablu torsadat
Producător DIPOL
NETSET
Tip cablu U/UTP
Utilizare Interior
Categorie 6A
Lungime cablu m 500
Clasă CPR B2ca s1a,d1,a
Proprietăți fizice
Conductor Material Cupru
Diametru mm
Izolarea conductorilor Material PE
Diametru mm
Torsadat culori alb-maro/maro, alb-albastru/albastru, alb-portocaliu/portocaliu, white-green/green
manta Diametru mm
grosime mm
Culoare RAL7032 (gri)
Gel filled Nu
Cablu purtător Nu
Splina Da
Abatere marcare metraj <0.5
Parametrii electrici
Impedanță Ohm 100
Viteza nominală de propagare NVP 74
Întârziere oblică ns/100 m <45
Asimetrie în capacitatea căilor de transmisie la sol pF/100 m 330
Rezistență DC Ohm/100 m
Asimetrie de rezistență <5
Pierdere de returnare 1 MHz ≥dB 20
4 MHz ≥dB 23
8 MHz ≥dB
10 MHz ≥dB 25
16 MHz ≥dB 25
20 MHz ≥dB 25
25 MHz ≥dB
31.25 MHz ≥dB
62.5 MHz ≥dB
100 MHz ≥dB
200 MHz ≥dB 18
250 MHz ≥dB
300 MHz ≥dB
500 MHz ≥dB
Atenuare 4 MHz ≤dB
8 MHz ≤dB
10 MHz ≤dB
16 MHz ≤dB
20 MHz ≤dB
25 MHz ≤dB
31.25 MHz ≤dB
62.5 MHz ≤dB 15
100 MHz ≤dB
200 MHz ≤dB
250 MHz ≤dB
300 MHz ≤dB
500 MHz ≤dB
NEXT (near-end crosstalk) 1 MHz ≤dB
4 MHz ≤dB
8 MHz ≤dB
10 MHz ≤dB
16 MHz ≤dB
20 MHz ≤dB
25 MHz ≤dB
31.25 MHz ≤dB
62.5 MHz ≤dB
100 MHz ≤dB
200 MHz ≤dB
250 MHz ≤dB
300 MHz ≤dB
500 MHz ≤dB
PSNEXT (diafonia aproape de sumă de putere) 1 MHz ≥dB
4 MHz ≥dB
8 MHz ≥dB
10 MHz ≥dB
16 MHz ≥dB
20 MHz ≥dB
25 MHz ≥dB
31.25 MHz ≥dB
62.5 MHz ≥dB
100 MHz ≥dB
200 MHz ≥dB
250 MHz ≥dB
300 MHz ≥dB
500 MHz ≥dB
ELFEXT 1 MHz ≥dB
4 MHz ≥dB
8 MHz ≥dB
10 MHz ≥dB
16 MHz ≥dB
20 MHz ≥dB
25 MHz ≥dB
31.25 MHz ≥dB
62.5 MHz ≥dB
100 MHz ≥dB
200 MHz ≥dB
250 MHz ≥dB
300 MHz ≥dB
500 MHz ≥dB
PSELFEXT (suma de putere diafonie la capătul îndepărtat) 1 MHz ≥dB
4 MHz ≥dB
8 MHz ≥dB
10 MHz ≥dB
16 MHz ≥dB
20 MHz ≥dB
25 MHz ≥dB
31.25 MHz ≥dB
62.5 MHz ≥dB
100 MHz ≥dB
200 MHz ≥dB
250 MHz ≥dB
300 MHz ≥dB
500 MHz ≥dB
Proprietăți mecanice
Temp. funcționare °C -30...+50
Temperatură instalare °C 0...+50
Raza minimă de îndoire pentru instalare în interior Diametru >8
Ambalaj
Bobina Diametru mm 380
Lăţime mm 385
diametrul orificiului bobinei mm 33