Suport tehnic
Detalii
RDC-316 R817101 receiver is one of the modules used in MMH-3000 headend, mounted in the UC-380 R81700 base unit. It receives one DVB-S/S2 (QPSK/8PSK) transponder and converts the signals into MPEG-TS digital stream that is processed by other modules. The module is also a transmodulator of one of the programs into an analog PAL channel.
There are two configuration options:
- MPEG-TS (transport stream) is fed to DM-316 R817121 modules (TS decoders / DSB modulators) converting the programs from the received transponder into PAL channels,
- MPEG-TS is fed to TRX-360 R81709 DVB-T modulator (COFDM). This configuration allows for conversion of satellite signals (including encrypted channels) to a digital DVB-T multiplex.
The RDC-316 panel has a CI slot, which in case of receiving encrypted programs, must be equipped with a suitable decoder (CAM) intended for the specific encryption system. In order to decode multiple channels, it has to be a professional, multi-stream conditional access module.
The receiver is equipped with a DSB PAL modulator. This means that for the proper functioning of the installation, it is necessary to preserve at least one channel gap between the output RF channels of the headend.
More on MMH-3000 headend you can read in the article :
.Specifications
Name | RDC-316 | |
Code | R817101 | |
RF input | frequency range | 950-2150 MHz |
level/impedance | 30-88 dBμV / 75 Ω | |
LNB power | 0/18 V & 400 mA max. | |
Symbol rate (SR) | 1...45 MS/s | |
MPEG-2 TS SR | 2...80 MS/s | |
Modulator | ||
TV standard | B/G/D/K/I/L/M/N | |
RF output | level/impedance | 100 dBμV / 75 Ω |
frequency range | 119-300; 470-862 MHz | |
Level adjustment range | 0...-15 dB | |
Carrier stability | +/- 20 kHz | |
Offset range | 2.25 MHz with 0.25 MHz step | |
Video carrier to audio carrier ratio | 12/16 dB | |
Depth of modulation (AM-video) | 81% | |
S/N ratio | > 55 dB | |
Intermodulation products (II and III order) | < -60 dB | |
Power | 5.5 VDC , 1.1 A | |
Operating temperature | 0...50°C | |
Dimensions / Weight | 45x115x232 mm / 0.46 kg |
Electrostatic discharge caution
The module contains electrostatic sensitive components. To minimize electrostatic discharge, observe the following precautions:
- Do not remove module from its anti-static plastic bag until you are ready to install it into the base unit.
- Hold the module only by its front panel.
- Do not place the module on an unprotected surface. Immediately after you remove the module from the base unit, you must insert it into its anti-static plastic bag.
- When the module is not in use, keep it in its anti-static plastic bag.
- Do not ship or store the module or base unit in/near strong electrostatic, electromagnetic or radioactive fields.