COŞUL MEU
Coşul este gol

Cabluri

CPR B2CA

Coaxial Cable 75 Ohm, TriSAT B2CA LSZH-FR+ class A+ 1.00/4.6/6.9 110 dB [500m]
Cod: E1022_500
Preţ fără TVAPreţ cu TVARabatValiditate  
2584,40 Lei3075,44 Lei0 %
Garanţie de 5 ani
Înlocuitori
E1020_500Cablu coaxial TRISET 75 ohmi (clasa A ++, B2CA, 120dB, 1.05 / 4.6 / 6.9) 500m
Coaxial Cable 75 Ohm, TriSAT B2CA LSZH-FR+ class A+ 1.00/4.6/6.9 110 dB [500m]
TRISAT B2CA cable close up (LSZH-FR+ sheath).
Coaxial Cable 75 Ohm, TriSAT B2CA LSZH-FR+ class A+ 1.00/4.6/6.9 110 dB [500m]
78% braid coverage – tinned copper.
Quality coaxial cable TRISET B2CA E1022_500 is suitable for RF/SAT antenna systems in commercial buildings. Cable with LSZH-FR+, halogen-free insulation used where increased safety levels are required in the event of a fire (schools, hospitals etc.). In the event of a fire, the cable does not spread flame, smoke emission is very low and the released gases are not corrosive.
It has an inner cooper conductor with a diameter of 1.00 mm and triple shield (Al/PET/Al+Sur foil (first) bonded to the dielectric + 78% density braid + Al/PET foil (second) boded to the sheath).
Key features:
  • conforms to Class A+ standard
  • complies with the requirements of the construction legislation
  • fire reaction class in accordance with CPR - B2ca-s1a,d1,a1
  • cable in LSZH-FR+ sheath
  • copper core 1.00 mm
  • low attenuation
  • excellent fit
  • high shielding efficiency
  • 78% braid coverage
  • 5-year warranty
The requirements for using cables with a specific reaction to fire class in a given type of building should be based on a risk analysis made by the installation designer or other national formal and legal documents. The CPR Directive does not impose on the EU Member States the requirements for types of buildings and associated cables with specific fire reaction classes. The reaction to fire class of cables and other conductors installed within evacuation routes should not be less than B2ca-s1b, d1, a1.
  • High-rise buildings (WW) with a height of more than 55 m above ground level
  • High-rise buildings (W) with a height of more than 25 m to 55 m above ground level or residential buildings with the number of floors above ground level from 9 to 18 inclusive
  • Buildings in human risk category ZL I with rooms intended for simultaneous presence of more than 50 people who are not permanent users, and not intended primarily for use by people with reduced mobility
  • Buildings in human risk category ZL II – intended primarily for use by people with reduced mobility, such as hospitals, nurseries, kindergardens, nursing homes
  • Buildings in human risk category ZL III – commercial buildings not classified unser ZL I and ZL II
  • Buildings in human risk category ZL IV – residential
  • Buildings in human risk category ZL V – collective residence not classified under ZL I and ZL II
  • PM and IN buildings (production buildings, warehouses, livestock etc.).
For more on cable fire resistance classes, read The CPR Directive - the new cable order
Coaxial Cable 75 Ohm, TriSAT B2CA LSZH-FR+ class A+ 1.00/4.6/6.9 110 dB [500m]
View of the cable
TRISAT cables are compliant with Construction Products Regulation (CPR) and EN 50575 standard that specifies reaction to fire performance requirements, test and assessment methods for cables used as building materials.
Coaxial Cable 75 Ohm, TriSAT B2CA LSZH-FR+ class A+ 1.00/4.6/6.9 110 dB [500m]
The 75 ohm TriSAT B2CA E1022 coaxial cable has been tested at the notified body L.S. Fire Testing Institute Srl with a number 2479 and has been awarded B2ca-s1a,d1,a1 reaction to fire class.
TriSAT B2CA complies with the EN50117 standard and A+ class requirements in the whole 5-3000 MHz transmission frequency range.
The cable complies with the requirements of the Regulation of the Ministry of Transport, Construction and Maritime Economy on technical conditions to be met by buildings and their location of November 22, 2012, for the cabling dedicated to TV/SAT systems.
RequirementsTriSAT B2CA specifications 
Category RG-6 or higherTriSAT cables are RG-6
category products with improved performance
Double shield:
aluminium foil + ≥ 77% density braid
Triple shield:
Al/PET/+Sur foil (first) bonded to the dielectric + 78% density braid + Al/PET foil (second) bonded to the sheath
Cooper inner conductor
with at least 1 mm diameter
 Cooper conductor with a diameter of 1.00 mm
Class AScreening efficiency
0.03...1 GHz ≥ 85 dB
1...2 GHz ≥ 75 dB
2...3 GHz ≥ 65 dB
Screening efficiency
0.03...1 GHz ≥ 97 dB
1...2 GHz ≥ 85 dB
2...3 GHz ≥ 75 dB
 Transfer impedance < 5 mΩ/m Transfer impedance < 0.9 mΩ/m
TriSAT B2CA complies with the following standards:
  • EN 60332-1-2 – test methods for reaction to fire of cables.
  • EN 50399 – heat release and smoke production measurement on cables during flame spread.
  • EN 60754-1/2 – corrosivity of gases evolved during the combustion.
  • EN 61034-2 – evaluation of formed smoke density.
The value of the cable's braid coverage (82%) remains in compliance with the requirements of the Ministry of Transport, Construction and Maritime Economy's regulation on the technical conditions to be met by buildings and their location.
High quality, triple shielded RG6 coaxial cable has an inner conductor made of +1.00 mm diameter copper wire+++, which ensures very low insertion loss. The core dose not corrode, and the cable is not stiff.
Optimum flexibility of the sheath allows for easy cable installation in shafts, as well as installation or junction boxes.
The cable is manufactured under strict quality standards, with tight tolerances.
In order to secure the minimum bend radius, flush mounted installations should be done with the use of protective conduits.
Specifications
Product typeCoaxial cable
TypeTriSAT B2CA
BrandTriSAT
Cable lengthm500
ApplicationsIndoor
Cable classRG-6
Compliance with relevant national legislationYes
CPR classB2ca
Gel-filled cableNo
Physical properties
ImpedanceOhm75
Screening efficiency classA+
Transfer impedance TImΩ/m<0.9
ConductormaterialCoper
diametermm1.00
DielectricfoamingPhysical
diametermm4.6
Shield
No. of plies3
First foilbonded to dielectricYES
materialAl/PET/Al+Sur
dimensionsµm18 x 12/15/12
total thicknessµm80
BraidmaterialTin-plated cooper
wire diametermm0.1
no. of wirespcs.16x10
braid coverage%78
Second foilbonded to sheathYes
materialAl/PET
ply thicknessµm20x30/19
total thicknessµm27
SheathmaterialLSZH-FR+
diametermm6.9
colorWhite (RAL 9010)
Electrical parameters
CapacitypF/m54
Wave reduction factor%82
Mechanical properties
Operating temperature°C-25...+70
Installation temperature°C-5...+40
Minimum bending radiusmm35 (single) 70 (repeated)
Weightkg/km56.20
Spoolwidthmm280
According to the EN50117 standard, coaxial cables are divided into the following classes, depending on their screening efficiency: C, B, A, A+, A++.
Classes of screening efficiency
Class\freq. range
5-30 MHz [mOhm/m]30-1000 MHz [dB]1-2 GHz [dB]2-3 GHz [dB]
C50756555
B1575 6555
A585 7565
A+2.595 8575
A++0.9105 9585

 

 

Price for 500m
Preţ fără TVAPreţ cu TVARabatValiditate  
2584,40 Lei3075,44 Lei0 %
Înlocuitori
E1020_500Cablu coaxial TRISET 75 ohmi (clasa A ++, B2CA, 120dB, 1.05 / 4.6 / 6.9) 500m
 
Coaxial Cable 75 Ohm, TriSAT B2CA LSZH-FR+ class A+ 1.00/4.6/6.9 110 dB [500m]
Cod: E1022_500
George Popescu
Consiliere clienţi
COMPLETAŢI
BIBLIOTECA
Nou în bibliotecă
RECOMANDĂRI
 
Regulamentul | Garanție | Reclamaţii | Download
| Cookies | Politica de confidentialitate Toate drepturile rezervate © 1996-2023 DIPOL sp.j.