- 1. Which video door entry system to choose: 2-Wire IP, 2-Wire HD or maybe IP?
2. Range of communication between individual devices
3. Devices included in the 2-Wire HD system
4. Suggested steps after purchasing devices
5. Procedure for updating the firmware in the door station and monitors
6. Description of switches on the door station and monitor - expansion options
7. Example topologies and device addressing
8. Access paths to the most important functions on the door station and monitors
9. Operation via the HikConnect app
10. Reset devices to factory settings
| Cable type | DS-KAD7061EY to DS-KAD7061EY | DS-KAD7061EY to Monitor | Monitor to Monitor | DS-KAD7061EY to DS-KAD7060EY | DS-KAD7060EY to DS-KAD7060EY-S | DS-KAD7061EY to Door station | Door station to Electric strike |
| UTP 5 x 0.2 mm2 AWG24 | 60 m | 60 m | 60 m | 60 m | 100 m | 60 m | - |
| Paired 0.28 mm2 AWG23 | 60 m | 40 m | 40 m | 40 m | 80 m | 40 m | 30 m |
| Straight 0.5 mm2 AWG20 | 60 m | 60 m | 60 m | 60 m | 100 m | 60 m | 50 m |
| Straight 1 mm2 AWG20 | 60 m | 60 m | 60 m | 60 m | 100 m | 60 m | 50 m |
| Paired 1 mm2 AWG17 | 60 m | 40 m | 40 m | 40 m | 80 m | 40 m | 100 m |
| Straight 1 mm2 AWG15 | 60 m | 40 m | 60 m | 60 m | 100 m | 60 m | 100 m |
- door station main module: DS-KD7003EY-IME2/A G73647
- 7” WiFi monitor, black: DS-KH7300EY-WTE2 G74026
- 7” WiFi monitor, white: DS-KH7300EY-WTE2/White G74027
- main audio, video and power distributor: DS-KAD7060EY G74828
- store distributor: DS-KAD7061EY G74830
- 48 VDC power supply: HDR-150-48 G74803
- EM 125 kHz card reader module DS-KD-E G73660
- Mifare 13.56 MHz card reader module: DS-KD-M G73662
- indicator module: DS-KD-IN G73664
- 6-button nameplate holder module: DS-KD-KK G73666
- 12-button nameplate holder module: DS-KD-K12 G73667
- keypad module: DS-KD-KP G73668
- display module with touch screen: DS-KD-TDM G73671
- blanking module: DS-KD-BK G73672
- 1-module flush-mounted housing: DS-KD-ACF1 G74340
- 2-module flush-mounted housing: DS-KD-ACF2 G74343
- 3-module flush-mounted housing: DS-KD-ACF3 G74346
- 1-module surface-mounted housing: DS-KD-ACW1 G74351
- 2-module surface-mounted housing: DS-KD-ACW2 G74354
- 3-module surface-mounted housing: DS-KD-ACW3 G74357
- rain shield for 1-module surface-mounted housing: DS-KABD8003-RS1 G74371
- rain shield for 2-module surface-mounted housing: DS-KABD8003-RS2 G74373
- rain shield for 3-module surface-mounted housing: DS-KABD8003-RS3 G74375
- checking if the devices have the latest firmware versions
- possible device update
- full reset of devices to factory settings
- configuration of devices according to the requirements of the target installation
- Updating the door station
- Monitor update
- DEC1, DEC2 – building number: 01-99
- DEC2, DEC3 - door station Number: 00 - main, 01-16 - secondary, 90-99 - external
- DEC5 - porter's lodge number (reserved)
- DEC6 - opening time of relay no. 2: 1-10 s (0 - 2 s, 1 - 1 s, 2 - 3 s, 3 - 4 s, 4-5 s, 5 - 8 s, 6 - 10 s, 7, 8, 9 - reserved)
- DEC1 – monitor number: 0 – main monitor, 1-3 – secondary monitor, 4-9 - unused
- DEC2, DEC3 – building number: 1-99
- DEC4, DEC5 – apartment number: 1-99
- DIP1, DIP2 - DIP1 = 0 and DIP2 = 0 multi-family mode, DIP1 = 1 and DIP2 = 0 - Villa mode, DIP1 = 0 i DIP2 = 1 – Professional studio mode
| SB | M1 | M1E1 | M2 | M2E1 | M3 | M3E1 | |
| DEC1 | 1 | 0 | 1 | 0 | 1 | 0 | 1 |
| DEC2 | 0 | 1 | 1 | 1 | 1 | 1 | 1 |
| DEC3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| DEC4 | 0 | 1 | 1 | 2 | 2 | 3 | 3 |
| DEC5 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| DEC6 | 0 | - | - | - | - | - | - |
| SB1 | SB2 | M1 | M1E1 | M2 | M2E1 | M3 | M3E1 | |
| DEC1 | 1 | 1 | 0 | 1 | 0 | 1 | 0 | 1 |
| DEC2 | 0 | 0 | 1 | 1 | 1 | 1 | 1 | 1 |
| DEC3 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 |
| DEC4 | 0 | 0 | 1 | 1 | 2 | 2 | 3 | 3 |
| DEC5 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| DEC6 | 0 | 0 | - | - | - | - | - | - |
| SB1 | M1 | M2 | M3 | M4 | M5 | M6 | M7 | M8 | |
| DEC1 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| DEC2 | 0 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| DEC3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| DEC4 | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
| DEC5 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| DEC6 | 0 | - | - | - | - | - | - | - | - |
- language selection and time setting: Configuration -> System -> System settings
- configuration of inputs (local opening buttons) and outputs (electric strike + door): Configuration -> Access control -> I/O settings
- setting the opening passwords (keyboard required): Configuration -> Access control -> Password settings
- call button configuration: Configuration -> Intercom -> Press button to call
- update monitors connected to the door station: Management
- add people, tags, configure user permissions: People management
- update door station, reset to factory settings: Maintenance and security
- change language: Settings -> General Settings -> System Language
- volume control: Settings -> Volume Settings
- setting up photo storage (microSD card required): Settings -> Preferences -> Photo settings
- connection stability testing: Settings -> General Settings -> Cable detection
- Door station (connection from laptop in AP mode): Maintenance & Security -> Backup and reset -> Restore Factory Settings -> Restore All
- Door station (connection from smartphone in AP mode): Configuration -> Maintenance -> Default -> Restore factory settings
- Monitor (local user interface): Settings -> Advanced settings -> Configuration -> System maintenance -> Restore all